GT 15KW Off Grid Solar Inverter

mærker: Lersion

produktets oprindelse: Kina

levering af tid: 7-15 dage

levere kapacitet: 150.000

1 Tyskland Infineon IGBT-modul;
2 Amerikas nye generation af GSP-chipteknologi;
3 50 ingeniører R&D teams, selvdesign og innovation kredsløb, system;
4 plus 12 års fabriksproducenterfaring, forbedring af kundefeedback
* high end * mere sikker * mere stabil * lang levetid

GT 15KW Off Grid Solar Inverter

GT Series 15KW Solar Inverter/ Hybrid Off Grid Inverter


1 Produktfunktioner til 15KW

  • Inverteren anvender MCU mikroprocessor fuldt digital SPWM kontrolteknologi, med ren sinusbølge output;

  • Unik dynamisk strømsløjfekontrolteknologi;

  • Super stærk belastningsbærende kapacitet, i stand til at tilpasse sig kapacitive, resistive, induktive og blandede belastninger;

  • Stærk overbelastning og slagfasthed, i stand til at modstå fuld belastning opstart;

  • Input overspænding/underspænding, output overspænding/underspænding, overtemperatur, overbelastning og kortslutningsbeskyttelsesfunktioner;

  • Høj effektivitet, lav støj, miljøbeskyttelse og energibesparelse;

  • Automatisk skift, muliggør ubemandet drift;

  • Stabil ydeevne, sikker og pålidelig, med en ultra lang levetid;

  • Kommunikation: USB/SNMP/GSM SMS;

  • WIFI fjernovervågning (valgfrit)


2 Anvendelse af 15KW

inverter for Islandoff grid solar inverter15kw hybrid inverterinverter for Islandoff grid solar inverter15kw hybrid inverter
beboelseHotel Villa Skib/øLandbrugsjordIkke-netområdeFabrik



3 Anvendelsesdiagram på 15KW

inverter for Island


4 tekniske parametre på 15KW

Inverter-tilstandGT080GT100GT120GT150GT180GT200GT250GT300
Hybrid off grid invertertilstandGTM080GTM100GTM120GTM150GTM180GTM200

Nominel effekt8KVA10KVA12KVA15KVA18KVA20KVA25KVA30KVA
Batterispænding96V/192V192V/240V/360V240V/360V
Størrelse: (L*B*Hmm)580*370*730740*400*930
pakke størrelse
(L*B*Hmm)
650*420*840820*480*1050
NW(KG)788592116130133150169
GW(KG)9097104132146149166185
Input
FaseL+N+G
AC-indgangsområde110V:85-138VAC;220V:170-275VAC
Indgangsfrekvens45Hz-65Hz
Produktion
Udgangsspændinginvertertilstand:110VAC/220V±5%;AC-tilstand:110VAC/220VAC±10%;
Frekvensområde
(AC-tilstand)
Automatisk sporing
Frekvensområde
(inverter-tilstand)
50Hz/60Hz±1 %
OverbelastningskapacitetAC-tilstand:(100%~110%:10min;110%~130%:1min;>130 %:1s ;)
invertertilstand:(100%~110%:30s;110%~130%:10s;>130 %:1s ;)
Spidsstrømforhold3:1 maks
Konverteringstid<10ms (typiske belastninger)
BølgeformRen sinusbølge
Effektivitet>95 % (80 % resistive belastninger)
Beskyttelse
funktioner
Batterioverspændingsbeskyttelse, batteriunderspændingsbeskyttelse, overbelastningsbeskyttelse,
kortslutningsbeskyttelse, overtemperaturbeskyttelse osv.
indbygget solar charge controller (juster)
Max ladestrøm50A60A100A120A
såsom videoovervågning og fotovoltaiske vandpumper)7 Tilslutningsdiagram for 15KW inverter96V/192V96V/192V
PV input voltage
range
96V:145V-230V;192V:260V-400V;
Max PV input96V:4800W
192V:9600W
96V:5760W
192V:11520W
96V:9600W
192V:19200W
96V:11520W
192V:23040W
Cooling methodFans cooling
environmental conditions
Operating
temperature
0-40
Battery life decreases at ambient temperatures above 25 degrees Celsius
Operation humidity<95%without condesing)
Operating altitude<1000m(with increase of 100m,it will reduce output of 1%) max5000m
Noise<58dB(distance to machine 1m)
Management
DisplayLCD+LED
Computer
communication
interface
RS232(adjust)
*The above data is for reference. If there is any change, please refer to the real object.



5 LED Color Touch Screen of 15KW

off grid solar inverter


 ON/OFFLong press to start the machine,Long press to shut down the machine;

②  PV indicator: indicator will be on when PV is available, and will be off when PV is not

available. When PV voltage is low, PV indicator will be off after flashing for 1

hour.(The built-in controller has this function.)

 Main power supply is always bright ,no main power is no bright.

Inverter indicator: will be on when working under inverter mode.

PV module parameters: display the current PV module input voltage, current,

power parameters;(The built-in controller has this function)

Displays the mode status of the current machine ;

Battery parameters: display the current battery voltage, the percentage of

capacity parameters;

Mains input: shows the current power state input voltage, frequency parameters;

Click here to access the Settings menu;

Load percentage: Displays the current inverter output voltage, frequency

parameters;


6 Working Mode of 15KW Off Grid Inverter

  • Mains Priority Mode (UPS)

Step 1: When there is mains power, it is directly output by the mains bypass and simultaneously charges the battery;

Step 2: When there is a sudden power outage or abnormality in the mains, the system automatically switches to battery inverter power supply within 5ms to ensure continuous operation of the load:

Step 3: When the mains power is restored, the system automatically switches to mains power supply and charges the battery at the same time; Explanation: If a photovoltaic panel is connected, under normal photovoltaic power generation, the battery will also be charged until it is fully charged,

 

  • Battery priority mode (photovoltaic priority)

Step 1: When the battery voltage is normal, the inverter power will be supplied by the battery (battery+photovoltaic) inverter output. Explanation: When the photovoltaic power generation power is greater than the electricity consumption power, the photovoltaic power will be directly inverter output for the load to use, and the excess electricity will be stored in the battery; If the photovoltaic power generation does not meet the electricity demand, the system will use batteries to supplement some of the electricity to meet the electricity demand

Step 2: When the battery is under voltage, the inverter power supply will automatically switch to the mains bypass output power supply, but the mains will not charge the battery; Explanation: Under voltage of the battery indicates that the photovoltaic power generation is not sufficient for use. This function mainly achieves complementary charging of urban electricity and ensures continuous use of electrical equipment. At this time, the battery needs to be charged by solar energy.

Step 3: When the photovoltaic panel or mains power is charged to the set value through the inverter power supply, the inverter power supply will automatically switch to the battery inverter output, achieving priority use of photovoltaic power generation.

Step 4: When there is a power failure, insufficient photovoltaic power generation, and insufficient battery voltage, the inverter will automatically turn off the output and enter sleep mode. Explanation: If the power supply returns to normal at this time, the inverter power supply will automatically turn on and switch to the power supply bypass output; If the mains power does not return to normal, it is necessary to wait until the photovoltaic system charges the battery to the set voltage, and the inverter will automatically turn on and resume the inverter output (this function is an unmanned function).

 

  • Energy saving mode (ECO)

When the inverter power supply is in energy-saving mode, the idle consumption is around 3W-5W, and only the chip is working, the inverter power supply will automatically cycle to detect the load power of the electrical appliance. When the load power is greater than 30W, the system will automatically start up and enter normal working mode within 5S to supply power to the load; When the load is unloaded (less than 30W), it automatically enters the energy-saving state within 5s; This feature greatly reduces unnecessary power waste in the system and minimizes idle consumption as much as possible.


  • Unattended

When the battery capacity is insufficient and the battery is under voltage, the inverter power supply will turn off its output and automatically enter a sleep state. The no-load loss is about 1W. When the photovoltaic system replenishes the battery voltage and returns to the set value, the inverter power supply will automatically turn on and resume output power supply. Description: This function is mainly applied to the use environment of pure off grid solar power generation without mains power and long-term unmanned operation, (such as video monitoring and photovoltaic water pumps)


7 Connection Diagram for 15KW Inverter


15kw hybrid inverter


inverter for Island


Factory Tour

Foshan Manufacture Base
Fremstillingsbase
Fremstillingsbase
SNEC Shanghai Solar Exhibition
SNEC Shanghai Solar Exhibition
Relaterede produkter
Produkt etiketter
Få den seneste pris? Vi svarer så hurtigt som muligt (inden for 12 timer)